1 |
Feed System |
Max feed per system: 9600 kg/day |
84 |
Drum Filters (estimated, including |
Side-stream units: 36 units – 1 unit per tank •40-micron mesh •99% removal of particles greater than 40-micron •1,875 m3/h each (11.9 MGD) •Tank mounted drum screen with connection •Influent TSS concentration 25 mg/L (est) •Temperature: 14°C •Salinity: 12-23 ppt (parts per thousand) Biofilter area units: 48 units (est) – actual number of units to be proposed by vendor including redundancy (e.g., N+1 per system): •Centralized sluicing pump station for •60-micron mesh •99% removal of particles greater than 60-micron •Total average Phase 2 flow: 135,000 m3/h •Average flow per system (6 systems): •Max flow: 125% of average flow •Influent TSS concentration: 25 mg/L (est) •Temperature: 14°C •Salinity: 12-23 ppt
460 V, 60 Hz, 3 phase |
6* |
Protein Skimmer Systems (Foam Fractionator) |
•Total average Phase 2 flow: •Average flow per system (6 systems): •(143 MGD) *Actual number of units •Max flow: 125% of average flow •Influent BOD concentration: 5-15 mg/L •Influent TSS concentration: 10-15 mg/L •Influent TAN (Total Ammonia Nitrogen): •50% TSS removal •CT: 10 mg-min/L •Temperature: 14°C •Salinity: 12-23 ppt 460 V, 60 Hz, 3 phase |
6 |
Biofilters (MBBRs) 4 MBBR tanks/system including: »media »mixers »O2 diffusers »Inlet dist. pipe and screens »Effluent screens |
•Total average Phase 2 flow: •Average flow per system (6 systems): •Max flow: 125% of average flow •Temperature: 14°C •Influent BOD concentration: ≤7 mg/L •Influent TSS concentration: ≤7.5 mg/L •Influent TAN concentration: 1.7 mg/L as N •Minimum effluent alkalinity: 100 mg CaCO3/L •Minimum 80% dissolved oxygen out of •Approx. TAN fish production to be removed 460 V, 60 Hz, 3 phase |
42 |
Degassers |
36 cascade-type side degassers •Average flow: 1,875 m3/hr. (11.9 MGD), each •Influent TSS concentration: 7.5 mg/L •Bypass of the degasser should be provided •Side degasser vendors are responsible to include in their proposal one (1) horizontal end-suction centrifugal pump per degasser to return the filtered water back to the tank. »Flow per pump 1,875 m3/hr. (11.9 MGD)Approx. Head 11.3 m (37 ft). »Vendor to confirm pump’s head according to the final arrangement. »Totally Enclosed, Fan-Cooled (TEFC) NEMA motors with variable-frequency drive (VFD) (alternative motor arrangements will be considered). »Include one (1) un-install backup 6 shallow or flooded biofilter systems with vacuum degasser treating 10% of total flow •Total average Phase 2 flow: 135,000 m3/hr. •Average flow per system (6 systems): •Max flow: 125% of average flow •Influent TSS concentration: 7.5 mg/L OG tanks effluent CO2 concentration: 12 mg/L Required CO2 influent concentration to the OG tanks: 5 mg/L (target concentration achieved by all degassing units in the system – side-stream and biofilter units. Vendor to confirm CO2 balance) Maximum nitrogen gas concentration in water: 100% 460 V, 60 Hz, 3 phase |